QSFP-DD Monitored Alarms
Table 76. QSFP-DD Monitored Alarms
Alarms |
|
Module |
|
S.No. |
Name |
1 |
Temperature |
2 |
Voltage |
3 |
TEC Current Magnitude |
4 |
Laser temperature |
Host |
|
S.No. |
Name |
1 |
Tx LOS |
2 |
Tx Cdr Loss of Lock |
3 |
Tx Adapttive Eq Failure |
4 |
Rx Output Status |
5 |
FEC Excessive Degrade(FED) |
6 |
FEC Detected Degrade(FDD) |
7 |
Remote Degrade |
8 |
Local Degrade |
9 |
Flexe Loss of pad block |
10 |
Flexe loss of Multiframe |
11 |
Flexe loss of frame |
12 |
Flexe instance ID mismatch |
13 |
Flexe calender mismatch |
14 |
Flexe instance map mismatch |
15 |
Flexe GID mismatch |
16 |
Tx local fault |
17 |
Tx remote fault |
18 |
Tx loss of alignment |
19 |
Rx local fault |
20 |
Rx remote fault |
21 |
Rx loss of alignment |
Media |
|
S.No. |
Name |
1 |
Rx Optical Power |
2 |
Tx Optical Power |
3 |
Tx Bias |
4 |
Rx LOS |
5 |
Rx Cdr Loss of Lock |
6 |
Tx Failure |
7 |
Tx Output Status |
8 |
Tx FIFO error alarm |
9 |
Tx Deskew Loss of Lock alarm |
10 |
Tx Reference Clock Loss of Lock alarm |
11 |
Tx CMU Loss of Lock alarm |
12 |
Tx Out of Alignment alarm |
13 |
Tx Loss of Alignment alarm |
14 |
Rx FIFO Loss of Lock alarm |
15 |
Rx Deskew Loss of Lock alarm |
16 |
Rx Out of Alignment alarm |
17 |
Rx Loss of Alignment alarm |
18 |
Rx Chromatic Dispersion Compensation Loss of Lock alarm |
19 |
Rx Demodulator Loss of Lock alarm |
20 |
Rx Loss of Multi Frame alarm |
21 |
Rx Loss of Frame alarm |
22 |
Remote PHY Fault alarm |
23 |
Local Degrade alarm |
24 |
Remote Degrade alarm |
25 |
FEC Detected Degrade over PM Interval alarm |
26 |
FEC Excessive Degrade over PM Interval alarm |
27 |
Laser Age |
28 |
Laser Frequency Error |
Performance Monitoring |
|
Host |
|
S.No. |
Name |
1 |
eSNR Input |
2 |
PAM4 Level Trans |
3 |
Pre-FEC BER |
4 |
FERC |
5 |
Tx Bits & Corrected Bits |
6 |
Tx Frames & Uncorrected Frames |
Media |
|
S.No. |
Name |
1 |
eSNR Input |
2 |
PAM4 Level Trans |
3 |
Pre-FEC BER |
4 |
FERC |
5 |
Mod Bias X/I |
6 |
Mod Bias X/Q |
7 |
Mod Bias Y/I |
8 |
Mod Bias Y/Q |
9 |
Mod Bias X_Phase |
10 |
Mod Bias Y_Phase |
11 |
CD - HG Short link |
12 |
CD - LG Long link |
13 |
DGD |
14 |
SOPMD - HG |
15 |
PDL |
16 |
OSNR |
17 |
eSNR |
18 |
CFO |
19 |
EVM_modem |
20 |
Tx Power |
21 |
Rx Total Power |
22 |
Rx Sig Power |
23 |
SOP ROC |
24 |
MER |
25 |
Clk recovery loop |
26 |
SOPMD - LG |
27 |
Rx Bits & Corrected Bits |
28 |
Rx Frames & Uncorrected Frames |
Example
Given a few examples of Alarms.
For Rx Optical Power & Rx Los:
2023 May 25 18:23:20.545 : OcNOS : NSM : CRITI : [IFMGR_IF_DOWN_2]: Interface cd52 changed state to down
2023 May 25 18:23:24.116 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Rx Optical Power[Low Alarm] detected on Lane[1] Port[52] module. Reading[100.000 dBm], Threshold[-28.239 dBm]. Vendor[SmartOptics ] Serial[214156190 ]
2023 May 25 18:23:24.164 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Rx LOS detected on Lane[1] Port[52] module. Vendor[SmartOptics ] Serial[214156190 ]
OcNOS#sh qsfp-dd 52 monitors media
Alarm Codes: TFIFO - Tx FIFO Error, TLOLDS - Tx Deskew Loss of Lock
TLOLRC - Tx Reference Clock Loss of Lock, TLOLCMU - Tx CMU Loss of Lock
TOOA - Tx Out of Alignment, TLOA - Tx Loss of Alignment
RFIFO - Rx FIFO Error, RLOLDS - Tx Deskew Loss of Lock
ROOA - Rx Out of Alignment, RLOA - Rx Loss of Alignment
RLOLCD - Rx Chromatic Dispersion Compensation Loss of Lock
RLOLD - Tx Demodulator Loss of Lock, RLOM - Rx Loss of Multi Frame
RLOF - Rx Loss of Frame, FDD - FEC Detected Degrade
FED - FEC Excessive Degrade, RPF - Remote Phy Fault
LD - Local Degrade, RD - Remote Degrade
Codes: [HA : High Alarm], [LA : Low Alarm], [HW : High Warning], [LW : Low Warning]
Port Number : 52
------------------------------------------------------------------------------------------------------------------
Monitors | Lane | Value | High Alarm | High Warning | Low Warning | Low Alarm | Unit |
------------------------------------------------------------------------------------------------------------------
Rx Optical Power | 1 | -- [LA] | 2.0 | 0.0 | -23.0 | -28.2 | dBm |
Tx Optical Power | 1 | -7.4 | 0.0 | -2.0 | -16.0 | -18.0 | dBm |
Tx Bias | 1 | 293.6 | 0.0 | 0.0 | 0.0 | 0.0 | mA |
------------------------------------------------------------------------------------------------------------------
VDM | Lane | Value | High Alarm | High Warning | Low Warning | Low Alarm | Unit |
------------------------------------------------------------------------------------------------------------------
Laser Age [DP]| 1 | 0.0 | 65534.0 | 58983.0 | 0.0 | 0.0 | % |
Pre-FEC BER Min In[DP]| 1 | 5.00e-01 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Max In[DP]| 1 | 5.00e-01 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Avg In[DP]| 1 | 5.00e-01 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Cur In[DP]| 1 | 5.00e-01 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Min Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Max Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Avg Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Curr Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Mod Bias X/I [DP]| 1 | 38.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
Mod Bias X/Q [DP]| 1 | 39.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
Mod Bias Y/I [DP]| 1 | 43.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
Mod Bias Y/Q [DP]| 1 | 41.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
Mod Bias X_Phase [DP]| 1 | 34.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
Mod Bias Y_Phase [DP]| 1 | 42.0 | 89.0 | 84.0 | 14.0 | 4.0 | % |
CD - HG Short link[DP]| 1 | 0.0 | -1.0 | -1.0 | 0.0 | 0.0 | Ps/nm |
CD - LG Long link [DP]| 1 | 0.0 | -20.0 | -20.0 | 0.0 | 0.0 | Ps/nm |
DGD [DP]| 1 | 0.0 | 655.3 | 655.3 | 0.0 | 0.0 | Ps |
SOPMD - HG [DP]| 1 | 0.0 | 655.3 | 655.3 | 0.0 | 0.0 | Ps^2 |
PDL [DP]| 1 | 0.0 | 6553.5 | 6553.5 | 0.0 | 0.0 | dB |
OSNR [DP]| 1 | 0.0 | 6553.5 | 6553.5 | 0.0 | 0.0 | dB |
eSNR [DP]| 1 | 0.0 | 6553.5 | 6553.5 | 0.0 | 0.0 | dB |
CFO [DP]| 1 | 0.0 | -1.0 | -1.0 | 0.0 | 0.0 | MHz |
Tx Power [DP]| 1 | -7.4 | 0.0 | -2.0 | -16.0 | -18.0 | dBm |
Rx Total Power [DP]| 1 | -46.5 | 13.0 | 10.0 | -18.0 | -21.0 | dBm |
Rx Sig Power [DP]| 1 | -40.0 | 13.0 | 10.0 | -18.0 | -21.0 | dBm |
SOP ROC [DP]| 1 | 0.0 | 65535.0 | 65535.0 | 0.0 | 0.0 | krad/s |
SOPMD - LG [DP]| 1 | 0.0 | 0.0 | 0.0 | 0.0 | 0.0 | Ps^2 |
-------------------------------------------------
Flag | Lane | Status (L) |
-------------------------------------------------
Rx LOS | 1 | True |
Tx Failure | 1 | False |
Rx CDR LOL | 1 | True |
---------------------------------------------------------------------------------
Link Performance | Lane | Average | Minimum | Maximum | Unit |
---------------------------------------------------------------------------------
Rx DSP CCD | 1 | 0 | 0 | 0 | ps/nm |
Rx DSP DGD | 1 | 0.00 | 0.00 | 0.00 | ps |
Rx Low Granularity SOPMD | 1 | 0.0 | 0.0 | 0.0 | ps^2 |
Rx PDL | 1 | 0.0 | 0.0 | 0.0 | dB |
Rx OSNR | 1 | 0.0 | 0.0 | 0.0 | dB |
Rx ESNR | 1 | 0.0 | 0.0 | 0.0 | dB |
Rx CFO | 1 | 0 | 0 | 0 | MHz |
Tx Power | 1 | -7.44 | -7.44 | -7.43 | dBm |
Rx Input Optical Power | 1 | -48.18 | -50.30 | -44.67 | dBm |
Rx Input Optical Signal Power | 1 | -40.00 | -40.00 | -40.00 | dBm |
Rx SOPCR | 1 | 0 | 0 | 0 | krads/s |
Rx MER | 1 | 0.0 | 0.0 | 0.0 | dB |
-------------------------------------------------------
FEC Performance | Lane | Value |
-------------------------------------------------------
Rx Bits | 1 | 0 |
Rx Corrected Bits | 1 | 0 |
Rx Frames | 1 | 0 |
Rx Uncorrected Frames | 1 | 0 |
For TX LOS & TX Cdr Loss:
2023 May 25 18:45:39.031 : OcNOS : NSM : CRITI : [IFMGR_IF_DOWN_2]: Interface cd0 changed state to down
OcNOS(config-if)#2023 May 25 18:45:40.340 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[1] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.349 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[1] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.373 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[2] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.381 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[2] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.406 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[3] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.414 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[3] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.438 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[4] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.446 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[4] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.471 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[5] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.478 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[5] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.503 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[6] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.511 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[6] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.535 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[7] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.543 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[7] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.568 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx LOS detected on Lane[8] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
2023 May 25 18:45:40.575 : OcNOS : CMM : CRITI : [CMM_CMIS_MODULE_MONITOR_2]: Tx Cdr Loss of Lock detected on Lane[8] Port[0] module. Vendor[SmartOptics ] Serial[214156344 ]
OcNOS(config-if)#end
OcNOS#show qsfp-dd 0 monitors host
Alarm Codes: FDD - FEC Detected Degrade, FED - FEC Excessive Degrade
LD - Local Degrade, RD - Remote Degrade
FLOPB - Flexe Loss of Pad Block, FLOMF - Flexe Loss of Multi-Frame
FLOF - Flexe Loss of Frame, FIIDM - Flexe Instance Id Mismatch
FCM - Flexe Calendar Mismatch, FIMM - Flexe Instance Map Mismatch
FGIDM - Flexe GID Mismatch, TLF - Transmit Local Fault
TRF - Transmit Remote Fault, TLOA - Transmit Loss of Alignment
RLF - Receive Local Fault, RRF - Receive Remote Fault
RLOA - Receive Loss of Alignment
Port Number : 0
-------------------------------------------------
Flag | Lane | Status (L) |
-------------------------------------------------
Tx LOS | 1 | True |
| 2 | True |
| 3 | True |
| 4 | True |
| 5 | True |
| 6 | True |
| 7 | True |
| 8 | True |
Tx CDR LOL | 1 | True |
| 2 | True |
| 3 | True |
| 4 | True |
| 5 | True |
| 6 | True |
| 7 | True |
| 8 | True |
Tx Adaptive Input Eq | 1 | Good |
| 2 | Good |
| 3 | Good |
| 4 | Good |
| 5 | Good |
| 6 | Good |
| 7 | Good |
| 8 | Good |
------------------------------------------------------------------------------------------------------------------
VDM | Lane | Value | High Alarm | High Warning | Low Warning | Low Alarm | Unit |
------------------------------------------------------------------------------------------------------------------
Pre-FEC BER Min In[DP]| 1 | 1.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Max In[DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Avg In[DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
Pre-FEC BER Cur In[DP]| 1 | 5.00e-01 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Min Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Max Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Avg Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
FERC Curr Input [DP]| 1 | 0.00e+00 | 2.05e+10 | 2.05e+10 | 0.00e+00 | 0.00e+00 | NA |
-------------------------------------------------------
FEC Performance | Lane | Value |
-------------------------------------------------------
Tx Bits | 1 | 0 |
Tx Corrected Bits | 1 | 0 |
Tx Frames | 1 | 0 |
Tx Uncorrected Frames | 1 | 0 |