clock-class

Use this command to denote the traceability of the time or frequency distributed by the clock.

Use the no parameter of this command to set the default value.

Applicable to non-Ethernet ports for PTP Clock Port mode.

Command Syntax

Copy
clock-class <0-255>
no clock-class

Parameters

<0-255>

A number that indicates the traceability of the time or frequency of the clock.

Command Mode

PTP Clock Mode

PTP Clock Port Mode

Default

In PTP Clock Mode, the default value is 248, and in PTP Clock Port Mode, the default value is 6 for the clock-port.

Applicability

This command was introduced in OcNOS version 3.0.

Example

Copy
(config)#ptp clock 0 profile g8275.1
(config-ptp-clk)#clock-class 3
 
(config-ptp-clk)#clock-port 1
(config-clk-port)#clock-class 7